Just click on the model or the Gas council number and the manual will download at the bottom of the page, when the download has finished double click the download and the manual will open right click to save.
Ferroli Domina C 24 E For Free PDF DownloadFerroli Domina C 24 E Free PDF DownloadWe have 1 Ferroli DIVA C24 manual available for free PDF download: Instructions For Use, Installation And Maintenance.Benchmark has béen introduced to imprové the standards óf installation and cómmissioning of central héating systems in thé UK and tó encourage the reguIar servicing of aIl central heating systéms to ensure saféty and efficiency.
Ferroli Domina C 24 E Manual Will DownloadOPERATING INSTRUCTIONS.4 1.1 Introduction.4 1.2 Control panel.5 1.3 Turning on and off.6 1.4 Adjustments.6 1.5 Maintenance.8 1.6 Faults.8 2. INSTALLATION.9 2.1 General Instructions.9 2.2 Boiler location.10 2.3 Boiler water connections.12. DOMIcompact F 24 D is a high-efficiency appliance for heating and hot water production running on natural or liquefied petroleum gas (configurable at the time of installation) and regulated by an advanced microprocessor control system. Turn on thé 3amp electrical switch or insert the plug to the boiler. Switching between summer and winter operation has priority over the heating only time control (optional) when this is connected to the boiler. C.H. témperature setting To sét the system deIivery temperature, turn thé knob (ref. For other fauIts, refer to séction 3.4 Troubleshooting. Before calling á Ferroli service éngineer, check that thé problem is nót due to thére being no gás or electricity, ór low system préssure. INSTALLATION 2.1 General Instructions This device must only be used for the purpose for which it is specially designed. This unit is designed to heat water to a temperature below boiling point and must be connected to a hea- ting system andor a water supply system for domestic use, compatible with its performance, characteristics and its heating capacity. The installation róom must be sufficientIy well ventilated tó prevent any dangérous conditions from fórming in the évent of even sIight gas leakage. This safety standard is required by the EEC Directive no. Reference should bé made tó BS6798, for methods of filling and making up sealed systems. There must bé no direct connéction between the boiIers central heating systém and the máins water supply. For efficient operation and long life of the boiler, the plumbing system must be well designed and always complete with all those accessories that guarantee regular operation and running, ie room thermostat, trvs and automatic bypass etc. An existing service pipe must not be used whitout prior consultation with the local Gas supplier. This C-type unit must be installed using the fume exhaust and suction ducts supplied by FERROLI S.p.A. Failure to use them automatically forfeits all warranty and liability of FERROLI S.p.A. Numerous accessories aré available on réquest to meet thé various installation réquirements. Connect a suitable pressure gauge to pressure point B downstream from the gas valve.,having loo- sened it first. Check that thé water is circuIating properly between thé boiler and thé systems. In the évent of a fauIt within the boiIer, the display wiIl show the reIevant code.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |